why compressor can not reaches the set working pressure

2016-01-18 15:44

1.Drain valve not close tightly,or pipe leakage(Fasten the drain valve)

2.Last stage safety valve failure(Adjust or replace last stare safety valve)

3.Piston rings worn(Replace piston rings)

4.Pipe connector loose(Fasten the connector)